Questions? Call Toll Free at 1-800-737-2112
Copyright © 2015 MAT Engine Technologies, LLC
ENG -
15
Maintenance
(Continued)
• Save all instructions
Spark Plug Model: Torch F7RTC
NOTICE
Only use the recommended spark plug or a spark plug with
the same temperature range. Using an improper spark
plug, an incorrect spark plug gap, or a dirty/fouled spark
plug can reduce engine performance and cause damage.
1. Stop engine and allow it to cool.
2. Remove spark plug wire from spark plug.
3. Use the spark plug wrench and rod (included with
blower) to remove the spark plug. (See Figure 13)
4. Visually inspect the spark plug for cracks or damage. If
cracked, replace spark plug.
5. Clean carbon deposits. If excessive carbon builds up,
replace spark plug.
6. Check that the gap of the spark plug is 0.028-0.031 in.
(0.7-0.8 mm). (See Figure 14)
7. Re-insert the spark plug and tighten using the spark
plug wrench and rod. (See Figure 13)
NOTE:
Torque of spark plug is 18-22 foot-pounds (25-30 Nm)
8. Reattach spark plug wire to spark plug.
Spark Plug
Wrench
and Rod
Figure 13
0.028 - 0.031 in
0.7 - 0.8 mm
Figure 14
WARNING
Never store the blower indoors with fuel in the fuel tank. Never store in an enclosed, poorly ventilated area where fumes
could reach an open flame, a spark or a pilot light as on a furnace, water heater or clothes dryer. Allow engine to cool
before storing unit.
WARNING
Do not remove gasoline while inside a building, near a fire, or while you smoke. Gasoline fumes can cause an explosion or a fire.
NOTE:
A yearly checkup or tune-up at an authorized service center will make sure that the blower will provide maximum
performance for the next season.
When the blower is put in storage for thirty days or more, the following steps should be followed to make sure the blower
is in good condition the next season.
1. Let the engine run until it is out of gasoline.
2. Change the oil by following instructions under “How to Change the Oil.”
3. Remove the spark plug from the cylinder. Pour one ounce 1 fl oz US (30 ml) of oil into the cylinder. Slowly pull the
recoil-start grip so that the oil will protect the cylinder. Install a new spark plug in the cylinder. Pull the starter handle
slowly until resistance is felt. Then, pull the starter handle slowly a few times to distribute the oil. This will close the
cylinder valves.
WARNING
DO NOT attach spark plug wire to spark plug when storing unit.
4. Clean blower. Remove all dirt, leaves, debris, grease, etc. from the blower - including cylinder cooling fans, recoil
starter cover holes, under fuel tank, and under muffler.
5. Check the blower for worn or damaged parts. Have damaged parts replaced if necessary.
6. Tighten any loose hardware.
7. Apply lubrication as directed in Maintenance section.
8. Put the unit in a building that has good ventilation.
9. Cover the blower with a breathing material.
How to Check the Spark Plug
D
How to Prepare for Storage
E