6.5.3: DYNAMICS
®
6.5.3: DYNAMICS
INPUT CHANNEL > TOUCHSCREEN > DYNAMICS BLOCK
Gate HOLD function
Adjust the Gate Hold Time
This is the time an activated gate will remain fully closed, before entering the 'release' phase.
Gate Release Time
Adjust the Gate Release Time
This is the time an activated gate will take to open, from its 'hold' state.
Gate Range
Adjust the Gate Range.
This is the difference between the normal signal level and the gated signal level.
Gate Side Chain Solo
Switches the Gate Side Chain signal to the Solo buss.
For monitoring the signal being used as the gate 'key' (The signal used for testing gate threshold).
Lo Cut Frequency
Adjust the cut-off frequency of the gate sidechain lo-cut filter.
Together with the gate hi-cut filter, this creates a band-pass filter for side chain control of the gate.
Sidechain Filter In
Inserts the gate Hi and Lo Cut side chain filters into the side chain signal path.
Together the gate lo-cut and high-cut side chain filters, create a band-pass filter for side chain control of the gate.