Remote Operation
5-31
MEASure:SCAN
Type: All
Channel
Description:
Sets the scanning mode of frame to load
module.
Syntax:
MEASure:SCAN ON
Enables the frame to scan the load
module.
MEASure:SCAN OFF
Disables the frame to scan the load
module.
Parameters: ON/1,
OFF/0
Example: MEAS:SCAN
ON
MEAS:SCAN
OFF
Query Syntax:
MEASure:SCAN?
Returns the scanning mode of the
frame.
Return Parameters: <NR1>
Query Example:
MEAS:SCAN?
Return Example:
1
MEASure:ALLVoltage?
Type: Channel-independent
Description:
Returns voltage measured at the input of the all load module.
Query Syntax:
MEASure:ALLVoltage?
Return Parameters: <aard> [Unit=Voltage]
Query Example:
MEAS:ALLV?
Return Example:
1.2, 2, 0, 0, 10.2, 0, 0, 0
MEASure:ALLCurrent?
Type: Channel-independent
Description:
Returns current measured at the input of the all load module.
Query Syntax:
MEASure:ALLCurrent?
Return Parameters: <aard> [Unit=Amper]
Query Example:
MEAS:ALLC?
Return Example:
0, 0, 0, 0, 5.12, 0, 12, 0