Remote Operation
5-23
CURRent:STATic:RISE/FALL
Type: Channel-specific
Description:
Sets current slew rate of constant current static mode.
Syntax: CURRent:STATic:RISE
<NRf+>
[suffix]
CURRent:STATic:FALL <NRf+> [suffix]
Parameters:
For valid value range, refer to respective specification.
Example:
CURR:STAT:RISE 2.5
Sets rise slew rate as 2.5A/
µ
S of
static load.
CURR:STAT:FALL
1A/
µ
S
Sets fall slew rate as 1A/
µ
S of static
load.
Query Syntax:
CURRent:STATic:RISE?
CURRent:STATic:FALL?
CURRent:STATic:RISE? MAX
CURRent:STATic:FALL? MIN
Return Parameters: <NR2> [Unit=A/
µ
S]
Query Example:
CURR:STAT:RISE?
Returns rise slew rate of static load.
Return Example:
2.5
CURRent:DYNamic:L1/L2
Type: Channel-specific
Description:
Sets Dynamic Load Current during constant current mode.
Syntax:
CURRent:DYNamic:L1 <NRf+> [suffix]
CURRent:DYNamic:L2
<NRf+>
[suffix]
Parameters:
For valid value range, refer to respective specification.
Example:
CURR:DYN:L1 20
Sets dynamic load parameter L1 = 20A.
CURR:DYN:L2 10
Sets dynamic load parameter L2 = 10A.
CURR:DYN:L1 MAX
Sets dynamic load parameter L1 =
maximum value.
CURR:DYN:L2 MIN
Sets dynamic load parameter L2 =
minimum value.
Query Syntax:
CURRent:DYNamic:L1?
CURRent:DYNamic:L2?
CURRent:DYNamic:L1?
MAX
CURRent:DYNamic:L2?
MIN
Return Parameters: <NR2> [Unit=Ampere]
Query Example:
CURR:DYN:L1?
Returns setting current in dynamic load
L1.
Return Example:
35.6
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com