Remote Operation
5-49
Return Parameters: <NR2> [Unit=Voltage]
Query Example:
VOLT:L1?
Returns the set voltage value of load L1.
Return Example:
0
VOLTage:CURRent
Type: Channel-specific
Description:
Sets the current limit of constant voltage mode.
Syntax: VOLTage:CURRent
Parameters:
For valid value range, refer to respective specification.
Example:
VOLT:CURR 3
Sets loading current limit as 3A during
constant voltage mode.
VOLT:CURR MAX
Sets loading current limit as the
maximum value during constant voltage
mode.
VOLT:CURR MIN
Sets loading current limit as the
minimum value during constant voltage
mode.
Query Syntax:
VOLTage:CURRent?
Return Parameters: <NR2> [Unit=Amper]
Query Example:
VOLT:CURR?
Return Example:
3
VOLTage:MODE
Type: Channel-specific
Description:
Sets the response speed of CV mode.
Syntax: VOLTage:MODE
FAST
VOLTage:MODE
SLOW
Parameters: FAST/1,
SLOW/0
Example:
VOLT: MODE FAST
VOLT:MODE
SLOW
Query Syntax:
VOLTage:MODE?
Return Parameters: <NR1>
Query Example:
VOLT:MODE?
Return Example:
0