Horizontal Pan/Vertical Tilt Setup
14
4
Move the joystick up/down to choose ON or OFF.
5
Press the
OPEN
key to confirm, or press
CLOSE
to cancel selection and exit from the menu screen.
SCAN LIMIT STOPS
When the camera scan mode is set to random or auto,
once the scan range is reached, the camera will turn the
other direction.
Activate SCAN LIMIT STOPS
1
Press “95” + hold the
PRESET
key for 2 seconds
to enter the main menu screen.
2
Move the cursor to <PAN/TILT SETUP>, and then
press the
OPEN
key to enter the <PAN/TILT
SETUP> menu.
3
Move the cursor to the SCAN LIMIT STOPS, and
then press the
OPEN
key to enter.
4
Move the joystick up/down to choose ON or OFF.
5
Press the
OPEN
key to confirm, or press
CLOSE
to cancel selection and exit from the menu screen.
Set SCAN LIMIT STOPS
•
Activate the scan range (SCAN LIMIT STOP = ON)
and then exit the menu.
•
Set the left limit: use the joystick and move the camera
to the left limit position. Press number key “92” + hold
the
PRESET
key for 2 seconds. The screen will show:
SCAN LEFT LIMIT, and the left limit will be set.
•
Set the right limit: use the joystick and move the
camera to the right limit position, then press number
key “93” + hold the
PRESET
key for 2 seconds. The
screen will show:
SCAN RIGHT LIMIT, and the right limit will be set.
MANUAL SPEED
The scan speed that can be set in manual scan mode is
30°/s, 60°/s, 90°/s and 120°/s.
1
Press “95,” and then hold the
PRESET
key for
2 seconds to enter the main menu screen.
2
Move the cursor to <PAN/TILT SETUP>, and then
press the
OPEN
key to enter the <PAN/TILT
SETUP> menu.
3
Move the cursor to MANUAL SPEED, and then
press the
OPEN
key to enter.
4
Move the joystick up/down to choose the desired
zoom speed.
5
Press the
OPEN
key to confirm, or press
CLOSE
to cancel selection and exit from the menu screen.
MANUAL LIMIT STOPS
When using the joystick to control the horizontal
panning, the camera will stop panning once it reaches
the scan limit. The scan limit can be configured as left
and right limit.
Activate MANUAL LIMIT STOPS
1
Press “95” + hold the
PRESET
key for 2 seconds
to enter the main menu screen.
2
Move the cursor to <PAN/TILT SETUP>, and then
press the
OPEN
key to enter the <PAN/TILT
SETUP> menu.
3
Move the cursor to MANUAL LIMIT STOPS, and
then press the
OPEN
key to enter.
4
Move the joystick up/down to choose ON or OFF.
5
Press the
OPEN
key to confirm, or press
CLOSE
to cancel selection and exit from the menu screen.
Set MANUAL LIMIT STOPS
1
Activate the manual scan range (MANUAL LIMIT
STOP = ON) and then exit the menu.
2
Set the left limit: use the joystick and move the
camera to the left limit position, then press number
key “90” + hold the
PRESET
key for 2 seconds.
The screen will show: MANUAL LEFT LIMIT,
and the left limit will be set.
3
Set the right limit: use the joystick and move the
camera to the right limit position, then press
number key “91” + hold the
PRESET
key for
2 seconds. The screen will show: MANUAL
RIGHT LIMIT, and the right limit will be set.