Setting procedure
Use the following procedure to set up dynamic detection and compensation.
1. Set the dynamic detection function to OFF. (DYNDETON=0[h]) (See Table 11.2-12)
2. Set the blemish detection area. (See Table 11.2-1)
3. Use DETSPEC to set the number of peripheral pixels. (See Table 11.2-20)
4. Set the number of detection-wait fields. (See Table 11.2-18)
5. Set the blemish reference dark level (DARKREFL/M). (See Table 11.2-19)
6. Use DETREFL/M and LARGEREFL/M to set the detection threshold levels. (See Table 11.2-14)
7. Turn the dynamic detection function ON. (DYNDETON=1[h]) (See Table 11.2-12)
8. Turn the blemish compensation function ON. (DEFON=1[h]) (See Table 11.2-11)
* To change the detection conditions, repeat steps 1 through 7.
* Set DYNDETON to 1[h] even if you do not plan to use dynamic detection and compensation.