- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
157
11.2.2. Blemish detection and compensation parameters
Detection Area Setting
These parameters set the blemish detection area. When AREA is set to “1[h]”, the detection area is displayed.
The location and size of the displayed box can be changed by setting HSRTL/M, VSRTL/M, HWIDTHL/M, and
VWIDTHL/M.
Table 11.2-1 Parameters for setting the detection area
Parameter
Description
AREA CAT11_Byte1_bit4
0[h]: Hides the blemish detection area
1[h]: Displays the blemish detection area
HSRTL CAT11_Byte13_bit0-7(LSB)
HSRTM CAT11_Byte17_bit0-1(MSB)
Used to set the horizontal start position of the
blemish detection area
VSRTL CAT11_Byte14_bit0-7(LSB)
VSRTM CAT11_Byte17_bit2-3(MSB)
Used to set the vertical start position of the
blemish detection area
HWIDTHL CAT11_Byte15_bit0-7(LSB)
HWIDTHM CAT11_Byte17_bit4-5(MSB)
Used to set the horizontal width of the blemish
detection area
VWIDTHL CAT11_Byte16_bit0-7(LSB)
VWIDTHM CAT11_Byte17_bit6-7(MSB)
Used to set the vertical width of the blemish
detection area
* These parameters can be used for both static detection and dynamic detection.
Fig 11.2-1 Detection Area Setting
Displaying blemish markers
This parameter is used to display marks in point where blemishes are detected. Even if a blemish has been
corrected and is no longer visible, when it is DEFMK=1[h], the marker will remain displayed. This makes it
appear as if the blemish has not been corrected. To check whether blemishes have been corrected, set
DEFMK to 0[h].
Table 11.2-2 Parameter for setting marker display
Parameter
Description
DEFMK CAT11_Byte1_bit1
0[h]: Hides marker
1[h]: Displays marker
Blemish
Detection
area
HSRTL/M
Display area
VSRTL/M
HWIDTHL/M
VWIDTHL/M