- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
140
Table 10.7-27 U6DBDWN
U6DBDWN
Category CAT12_Byte11_bit2
(1bit)
Outline
ON/OFF setting for minus gain.
Conditions
CRLESSON=1[h]
Available settings range
0[h],1[h] 1bit
Initial value
0[h]
Description
0[h] : OFF / 1[h] : ON
Notes
Color-rollingless AWB mode operation frames
In addition to the ATW operation frames, the SS-HQ1 also has operation frames for color-rollingless AWB mode.
Two types of operation frames can be set and turned on and off independently.
Table 10.7-28 CRFRMOFF
CRFRMOFF
anti Color-Rolling FRaMe OFF
Category CAT15_Byte44_bit0
(1bit)
Outline
ON/OFF setting for color-rollingless AWB operation frames.
Conditions
CRLESSON=1[h]
Available settings range
0[h],1[h] 1bit
Initial value
0[h]
Description
0[h] : ON / 1[h] : All OFF
When this is 1[h], frame 1 and frame 2 are both turned off.
See "Fig 10.7-5 Operation frame of Color-rollingless" for frame 1 and
frame 2.
Notes