8-2
8-1 Recording and Playback IRIG-B Time Code Signal
Connecting a IRIG-B Time Code Signal
The following IRIG-B time code signal can be connected.
Code
: Amplitude modulation code (AC code)
Carrier frequency
: 1 kHz
Voltage range
: ±1 to ±10 Vpk
Modulation amplitude ratio
: 1:3
Time code generator
Time code reader
1
Set the digital switch IRIG ON/OFF on the rear panel to the ON (upper/factory setting
position).
2
Use a BNC cable (sold separately) to connect the AUX-2 (IRIG-B) IN connector on
the rear panel and the IRIG-B time code signal from an IRIG time code generator.
If necessary, use a BNC cable (sold separately) to connect the AUX-2 (IRIG-B) OUT
connector on the rear panel and IRIG time code reader.
!
CAUTION
If the digital switch IRIG ON/OFF is set to OFF, the IRIG-B time code signal cannot be
detected properly.
CANNON
XLR 32F
REMOTE
AUX-2 (IRIG-B)
IN
OUT
EXT. CONT
AUX-1 (DIGITAL)
IN
OUT
COM
TRIG/REC
IN
SYNC
DC IN
AC FUSE
T4A
DC BREAKER
RAL / HLD
9.6 / 19.2
TRG S/M
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
SELECTOR
AC IN
STAND BY
OPTION SLOT 1
OPTION SLOT 2
ANALOG
OUTPUT
LSB DIGITAL
OUTPUT
1
2
3
4
5
6
7
8
D1
D2
D3
D4
1
2
3
4
5
6
7
8
9
14
15
16
17
25
24
23
22
13
12
11
10
19
20
21
18
9
8
7
6
5
4
3
2
1
220V
240V
8 7 6 5 4 3 2 1
!
PTRG OFF/ON
HRS
IRIG ON/OFF
8 7 6 5 4 3 2 1
!