1-20
38
(GB)
Troubleshooting
If the projector appears to be operating erratically, try to diagnose and correct the problem, using the following
guide. If the problem still persists, consult with qualified Sony personnel.
Symptom
Cause
Remedy
The power is not turned on.
The power has been turned off and on
with the I /
u
key at a short interval.
Wait for about 90 seconds before turning on the
power
(see page 22 (GB)).
The lamp cover is detached.
Close the lamp cover securely
(see page
36 (GB)).
The air filter cover is detached.
Close the air filter cover securely
(see page
37 (GB)).
No picture and no sound.
Cable is disconnected.
Check that the proper connections have been
made
(see pages 18 (GB) to 21 (GB)).
Wrong connection.
Check that the proper connections have been
made
(see pages 18 (GB) to 21 (GB)).
Input selection is incorrect.
Select the input source correctly using the INPUT
key
(see page 22 (GB)).
No picture or no sound.
Either the picture or the sound is cut off.
Press the MUTING keys to release the muting
function
(see page 23 (GB)).
No picture.
The computer signal is not set to output
to external monitor.
Set the computer signal to output to external
monitor
(see page 18 (GB)).
The computer signal is set to output to
both the LCD of the computer and
external monitor.
Set the computer signal to output only to external
monitor
(see page 18 (GB)).
The picture is noisy.
Noise may appear on the background
depending on the combination of the
numbers of dot input from the connector
and numbers of pixel on the LCD panel.
Change the desktop pattern on the connected
computer.
When inputting sound through
INPUT A connector, sound
comes through one channel
only.
Monaural sound is being input through
the INPUT A connector.
Input stereo sound.
The picture input from the
INPUT A connector is too
bright.
The 75-ohm termination switch on the
bottom of the VPL-XC50U/E/M is set to
OFF.
Set the 75-ohm termination switch to ON.
The picture from INPUT A
connector is colored strange.
Setting for INPUT-A in the SET
SETTING menu is incorrect.
Select RGB or COMPONENT for INPUT-A in the
SET SETTING menu according to the input signal
(see page 31 (GB)).
“Please check INPUT-A in
SET SETTING.” appears in
spite of inputting the correct
signal from INPUT A.
Setting for INPUT-A in the SET
SETTING menu is incorrect.
Select RGB or COMPONENT for INPUT-A in the
SET SETTING menu according to the input signal
(see page 31 (GB)).
On-screen display do not
appear.
STATUS in the SET SETTING menu has
been set to OFF.
Set STATUS in the SET SETTING menu to ON
(see page 31 (GB)).
Color balance is incorrect.
Picture has not been adjusted properly.
Adjust the picture
(see pages 26 (GB) and 27
(GB)).
Projector is set to wrong color system.
Set COLOR SYS in the PICTURE CTRL menu to
match the color system being input
(see page 27
(GB)).
The picture is too dark.
Contrast or brightness has not been
adjusted properly.
Adjust the contrast or brightness in the PICTURE
CTRL menu properly
(see page 26 (GB)).
The picture is not clear.
Picture is out of focus.
Adjust the focus
(see page 23 (GB)).
Condensation has occurred on the lens.
Leave the projector for about two hours with the
power on
(see page 34 (GB)).
39
(GB)
Symptom
Warning messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Caution messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
Cause
Remedy
The LAMP/COVER indicator
flashes.
The lamp cover or the air filter cover is
detached.
Attach the cover securely
(see pages 36 (GB) and
37 (GB)).
The LAMP/COVER indicator
lights up.
The lamp has reached the end of its life.
Replace the lamp
(see page 36 (GB)).
The lamp becomes a high temperature.
Wait for 90 seconds to cool down the lamp and
turn on the power again
(see page 22 (GB)).
The TEMP/FAN indicator
flashes.
The fan is broken.
Consult with qualified Sony personnel.
The TEMP/FAN indicator
lights up.
The internal temperature is unusually
high.
Check to see if nothing is blocking the ventilation
holes.
The Remote Commander
does not work.
The Remote Commander batteries are
dead.
Replace with new batteries
(see page 16 (GB)).
The COMMANDER ON/OFF switch is
set to the OFF position.
Set the switch to ON position
(see page 16 (GB)).
The cable is connected to the CONTROL
S OUT jack.
Disconnect the cable
(see page 16 (GB)).
The front/rear remote control detector is
near the fluorescent lamp.
Change the setting of SIRCS RECEIVER in the
SET SETTING menu
(see page 32 (GB)).
The laser pointer is not
emitted.
The batteries are dead.
Replace with new batteries
(see page 16 (GB)).
The Remote Commander is used as
wired without batteries.
Install batteries
(see page 16 (GB)).
The joystick, R CLICK, or L
CLICK key does not function.
The mouse port on the computer does
not recognize the mouse cable.
Restart the computer.
Meaning
Remedy
High Temperature!
Power off in 1 min.
Internal temperature is too high.
Turn off the power.
Check to see if nothing is blocking the ventilation
holes.
Frequency is out of range!
This input signal cannot be projected as
the frequency is out of the acceptable
range of the projector.
Input a signal that is within the range of the
frequency.
The resolution setting of the output
signal of a computer is too high.
Set the setting of output to the SVGA
(see page 18
(GB)).
Meaning
Remedy
NO INPUT
No input signal
Check connections.
Not applicable!
You have pressed the wrong key.
Press the appropriate key.
Please check INPUT-A in SET
SETTING.
You have input RGB signal from the
computer when INPUT-A in the SET
SETTING menu is set to COMPONENT.
Set INPUT-A correctly.
Summary of Contents for RM-PJM600
Page 48: ......
Page 76: ......
Page 77: ...8 1 8 1 A B C D E F G H 1 2 3 4 5 SECTION 8 DIAGRAMS 8 1 FRAME SCHEMATIC DIAGRAM FRAME FRAME ...
Page 99: ...8 23 8 23 A B C D E F G H 1 2 3 4 5 GAA GAA GAA B SIDE SUFFIX 11 GAA A SIDE SUFFIX 11 ...
Page 101: ...8 25 8 25 A B C D E F G H 1 2 3 4 5 GA GA ...
Page 103: ...8 27 8 27 A B C D E F G H 1 2 3 4 5 GB GB ...
Page 104: ......