![Sony PMW-300 Service Manual Download Page 97](http://html.mh-extra.com/html/sony/pmw-300/pmw-300_service-manual_1323744097.webp)
3-5.
Error Code List
When warning, caution, or checking of operation is needed, the unit indicates a message on the LCD monitor, blinks
the TALLY LED, and beeps a warning.
When an error is detected, the error code is displayed on the LCD monitor and operation is stopped. Error codes are
displayed as E-xxxxx (x: number).
Error code
Description
Service action
E-15030
System error
Repair the DPR-355 board or replace it.
E-17001
The media ID data in the EEPROM is abnormal
Rewrite the media ID data in the EEPROM.
For details, contact your local Sony Sales Office/Serv-
ice Center.
E-17002
The image processor block does not start
Repair the DCP-64 board or replace it.
E-17003
The display block does not start
Repair the DCP-64 board or replace it.
E-17004
The media block does not start
Repair the DPR-355 board or replace it.
E-17005
The image processor block startup processing is ab-
normal
Repair the DCP-64 board or replace it.
E-17006
The display block startup processing is abnormal
Repair the DCP-64 board or replace it.
E-17007
The media block startup processing is abnormal
Repair the DPR-355 board or replace it.
E-17014
The lens communication is abnormal
Check the connection of the DCP-64 or HN-413 board.
When there is no problem with the connection, replace
the DCP-64 or HN-413 board.
E-17015
The media block is abnormal
Repair the DPR-355 board or replace it.
E-17016
The lens switch status cannot be acquired
Check the connection around the HN-413 board. When
there is no problem with the connection, replace the
relevant switch board or the HN-413 board.
E-17017
Media block internal error
Repair the DPR-355 board or replace it.
E-4xxxx
If two or more errors occur simultaneously
The highest-priority error is displayed.
When an error with a higher priority has been cleared, the one with the next priority is displayed.
PMW-300