![Sony PMW-300 Service Manual Download Page 92](http://html.mh-extra.com/html/sony/pmw-300/pmw-300_service-manual_1323744092.webp)
Item2 (Display block diagnosis)
The display block diagnosis tests the following contents.
ID
Diagnosis
Error value
Type1/2
Note
0x01
Communication signal line test of COPRO
(SAD)
-1: Connection error
1, 2
—
0x02
Communication signal line test of LCD
(SAD)
-1: Connection error
1, 2
—
0x03
Communication signal line test of IO Ex-
pander (SAD)
-1: Connection error
1, 2
—
Item3 (Media block diagnosis)
The media block diagnosis tests the following contents. An error value of "-6" is displayed in some cases with any ID
other than the following IDs, but this is not a problem.
Be sure to turn off the power after Item3 has been executed.
ID
Intended device
Diagnosis
Error value
Type1/2
Note
0x01
—
Command response on-
ly
Normal end "0" is always
returned.
2
Startup must be com-
pleted
0x06
USB Device
Register Read/Write
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x08
USB Device
Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x09
i.LINK
Register Read/Write
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x0A
i.LINK
Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x0B
USB Host
Register Read/Write
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x0D
USB Host
Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x11
TK-1(SlotA)
Data Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x12
Torino
Data Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x13
TK-1(SlotB)
Data Read/Write
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x14
PIFC
POWSW
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x15
SPA
POWSW
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x16
NATH
Data Read/Write
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x20
NOR-FlashROM
NOR-Flash ROM data
matching check
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x21
ExpressCard
ExpressCard power
switch ON/OFF control
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x22
(SlotA)
ExpressCard overcur-
rent detection
Non-installation "-6" is al-
ways returned.
1
Startup must be com-
pleted
0x23
LED
LED blink check
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
0x24
LED
LED blink check
Refer to "Details of diag-
nosis"
1
Startup must be com-
pleted
Continued
PMW-300
3-8