PCS-G70N/G70NP/G70NP2
PCS-G70S/G70SP
4-3 (E)
Update the file to the
latest version.
Is updating complete?
(Check the screen.)
No
No
Yes
Yes
Check the
IC101, IC2105/CPU-382,
and the peripherals.
Check the following
.
IC2001/CPU-382,
and the peripherals
.
FTP setting (PC side)
.
IP address (unit side)
.
Ping sending testing
Check the following
.
IC504/CPU-382,
and the peripherals
.
MS- 73 board
.
FFC in the unit
Set correctly.
.
Program data in the Memory Stick is old.
.
Incorrect folder
Connect the terminal PC to
the unit with serial interface,
and turn on the power
of the unit.
Start Diag mode from
the application by inputting
the following command.
pcsdb>
goto diag
FFC: Flexible flat cable
BT: Automatic check item during boot-up
AD: Diag check item by entering "
auto
" command
START
BT-00
Are the connection of
cable and connector, and
the communication setting
conditions correct?
No
Is the following prompt
displayed by pressing the
return key after the
message is stopped?
pcsdb>
When Memory Stick is inserted (Example)
filecnt<38.885>ms status change (Insert)
opecnt <38.885>opecnt> Poweron req illegal state (not standby/sleep)
rfilecnt<39.633>MS Info:
Media : STD [16MB]
OS Type: 01, Total Sector: 31591
filecnt<39.647>MS init succeed!!
opecnt <39.649>opecnt> Mscnt [INSERT]
opecnt> Not found Private Phone Book
opecnt> Mail to Uicnt [MS INSERT]
When Memory Stick is removed (Example)
filecnt<11.070>ms status change (Eject)
filecnt<11.571>MS eject
opecnt <11.572>opecnt> Mscnt [EJECT]
opecnt> Mail to Uicnt [MS EJECT]
Yes
AD-00
Turn off the power, and start Diag mode directly.
(Turn on the power while pressing
[CTRL]+D keys by terminal PC.)
BT-00
AD-00
Yes
No
What is used for
updating?
FTP is used.
Memory Stick is used.
No
Is the following
message displayed after
the Memory Stick is
inserted or removed?
Yes
Update function block simple check
Application image file
update completed?
4-1-4. Operation Check in Self-diagnosis Mode