67
2-3-9. SS-1007 Board, WF-1008 Board
Preparation
1. Remove the top cabinet and the bottom cover. (Refer to “2-2. Top Cabinet, Bottom Cover”.)
2. Remove the inside panel. (Refer to “2-3. Inside Panel”.)
3. Remove the lithium battery. (Refer to “2-3-1. Lithium Battery”.)
4. Remove the HP-1015 board. (Refer to “2-3-2. HP-1015 Board”.)
5. Remove the FU-1001 board assembly. (Refer to “2-3-5. FU-1001 Board”.)
6. Remove the TG-1005 board assembly and the SH-1030 board. (Refer to “2-3-6. TG-1005 Board,
7. Remove the WB-1002 board assembly. (Refer to “2-3-7. WB-1002 Board”.)
8. Remove the VSW-1001 board. (Refer to “2-3-8. VSW-1001 Board, SW-1037 Board”.)
Procedure
1. Remove the three screws, and then remove the REC button base assembly in the direction of the
arrow.
Note
When installing the REC button base assembly, fix the WF-1008 board to the hook.
REC button
base assembly
WF-1008 board
TP2 x 5
Hole
Hole
Bosses
Hook