6-41
HVR-M15J/M15U/M15N/M15E/M15P/M15C
D
1
(decimal)
D
2
(decimal)
H
1
(hexadecimal)
(Service model code)
00001 to 65535
D
1
FE
65536 to 131071
D
1
−
65536
FE
131072 to196607
D
1
−
131072
FE
196608 to 262143
D
1
−
196608
FE
262144 to 327679
D
1
−
262144
FE
327680 to 393215
D
1
−
327680
FE
393216 to 458751
D
1
−
393216
FE
458752 to 524287
D
1
−
458752
FE
524288 to 589823
D
1
−
524288
FE
589824 to 655359
D
1
−
589824
FE
655360 to 720895
D
1
−
655360
FE
720896 to 786431
D
1
−
720896
FE
786432 to 851967
D
1
−
786432
FE
851968 to 917503
D
1
−
851968
FE
917504 to 983039
D
1
−
917504
FE
983040 to 999999
D
1
−
983040
FE
Table 6-2-2
4) Enter H
1
to address: 09 on page: 13.
Example: If H
1
= FE,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 09, and set data: FE, then press
the PAUSE (Write) button.
5) From Table 6-2-3, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
= 12345.
D
3
= 12288
6) From Table 6-2-3, obtain a hexadecimal number that corre-
sponds to D
3
, and it is assumed to be H
3
.
Example: If D
3
= 12288,
H
3
= 3000
7) Caluculate D
4
using following equations (decimal
caluculation). (0 D
4
225)
D
4
= D
2
– D
3
Example: If D
2
= 12345 and D
3
= 12288,
D
4
= 12345 – 12288 = 57
8) Convert D
4
into a hexadecimal number to obtain H
4
. (See Table
6-3-1 “Hexadecimal - decimal conversion table” in 6-3. Ser-
vice Mode)
Example: If D
4
= 57,
H
4
= 39
9) Enter higher two digits of H
3
to address: 0A on page: 13.
Example: If H
3
= 3000,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0A, and set data: 30, then press
the PAUSE (Write) button.
10) Enter H
4
to address: 0B on page: 13.
Example: If H
4
= 39,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0B, and set data: 39, then press
the PAUSE (Write) button.
11) Select page: 0, address: 10, and set data: 00.
12) Select page: 0, address: 01, and set data: 00.
2-3.
SYSTEM CONTROL SYSTEM ADJUSTMENTS
1.
Node Unique ID No. Input
Note 1:
Perform “1-2. Input of Serial No.” if the data on page 13
has been cleared and original node unique ID No. is un-
certain.
Usually, read the data on page 13 before repair, and write
it after repair.
Note 2:
If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
1-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory).
Page
13
Address
04, 05, 06, 07, 08
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 01.
3) Select page: 3 (13), and enter the following data.
Note 3:
Each time the data is set, press the PAUSE (Write) but-
ton on the adjusting remote commander.
Address
Data
04
08
05
00
06
46
07
01
08
02
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
1-2. Input of Serial No.
Write the serial No. and model code to the EEPROM (nonvolatile
memory).
In writing the serial No., a decimal number should be converted
into a hexadecimal number
Page
13
Address
09, 0A, 0B
1) Select page: 0, address: 01, and set data: 01.
2) Read the serial No. from the model name label, and it is as-
sumed to be D
1
.
Example: If serial No. is “77881”,
D
1
= 77881
3) From Table 6-2-2, obtain D
2
and H
1
that correspond to D
1
.
Example: If D
1
= 77881,
D
2
= D
1
– 65536 = 12345
H
1
= FE
Summary of Contents for HVR M15U - Professional Video Cassete recorder/player