HVR-M15J/M15U/M15N/M15E/M15P/M15C
4-2. COMPONENT OUT Y Level Adjustment
(D1 SMPTE) (VD-036 board)
Mode
E-E
Signal
No Signal
Measurement Point
Y terminal of COMPONENT OUT
jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
93
Specified value
Y level: A = 1000
±
10 mVp-p
Sync level: B = 300
±
10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Preparations”.
2
C
93
Change the data and set the Y
signal level (A) to the
specified value.
3
C
93
Press PAUSE (Write) button.
4
Check the sync signal level
(B) to the specified value.
5
Perform “Processing after
Complete Adjustment”.
H
A
B
Fig. 6-2-7
4-3. COMPONENT OUT Pb Level Adjustment
(D1 SMPTE) (VD-036 board)
Mode
E-E
Signal
No Signal
Measurement Point
Pb/Cb terminal of COMPONENT
OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
94
Specified value
Pb level: A = 525
±
10 mVp-p
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Preparations”.
2
C
94
Change the data and set the
Pb signal level (A) to the
specified value.
3
C
94
Press PAUSE (Write) button.
4
Perform “Processing after
Complete Adjustment”.
H
A
Fig. 6-2-8