6-35
HVR-M15J/M15U/M15N/M15E/M15P/M15C
2-2.
INITIALIZATION OF 8, 9, A, B, C, D, 13, 18, 1A,
1B, 1C, 1D PAGE DATA
Note :
When reading or writing the 13, 18, 1A, 1B, 1C or 1D
page data, select page: 0, address: 10, and set data: 01,
then sclect 3, 8, A, B, C or D page. The 13, 18, 1A, 1B,
1C or 1D page can be chosen by this data setting.
After reading or writing, reset the data or page: 0, ad-
dress: 10 to “00”.
2.
Modification of 8, 9, C, 13, 18, 1C, 1D Page Data
If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 8, 9, C, set data: 00 to page: 0,
address: 10, and then select pages 8, 9, C.
3) If modification of data on pages 13, 18, 1C, 1D, set data: 01 to
page: 0, address: 10, and then select pages 3, 8, C, D.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 8, 9, C, 13, 18, 1C,
1D page data:
Order Page Address Data
Procedure
1
7
01
DB
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data changes to
“01”.
4
Press the RESET button at
the rear panel of the unit
using a thin and long pin.
2-2-1.
Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data
1.
Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data
Note1:
If “Initialization of Pages 8, 9, C, 13, 18, 1C, 1D” is ex-
ecuted, all data on pages 8, 9, C, 13, 18, 1C, 1D are ini-
tialized. (Only an individual page cannot be initialized)
Note2 :
If the 8, 9, C, 13, 18, 1C, 1D page data has been initial-
ized, the following adjustments need to be performed
again.
1) Modification of 8, 9, C, 13, 18, 1C, 1D page data
2) Node unique ID No. input
3) Servo, RF system adjustments
4) Video system adjustments
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
9
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
13
Adjustment Address
00 to FF
Adjustment Page
18
Adjustment Address
00 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Adjustment Page
1D
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE (Write) button.
(Note 3)
3
3
81
00: Initializing all areas
01: Initializing other than
adjustment address
4
3
80
0C
Press PAUSE (Write) button.
Check the data changes to
5
3
80
“1C”.
6
Press the RESET button at
the rear panel of the unit
using a thin and long pin.
7
3
76
Check the data is “00”.
Perform “Modification of 8,
8
9, C, 18, 1C, 1D Page Data”.
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
Summary of Contents for HVR M15U - Professional Video Cassete recorder/player
Page 243: ......