6-49
HVR-M15J/M15U/M15N/M15E/M15P/M15C
2-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Order Page Address Data
Procedure
1
0
10
01
2
C
0F
00
Press PAUSE (Write) button.
(1C)
3
8
04
80
Press PAUSE (Write) button.
(18)
4
8
00
00
Press PAUSE (Write) button.
(18)
5
8
01
00
Press PAUSE (Write) button.
(18)
6
8
06
00
Press PAUSE (Write) button.
(18)
7
0
10
00
8
0
01
00
2-4. VIDEO OUT Level Check (VD-036 board)
Mode
E-E
Signal
No signal
Measurement Point
VIDEO OUT jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Specified value
Sync level: A = 286
±
18 mVp-p(NTSC)
A = 300
±
18 mVp-p(PAL)
Burst level: B = 286
±
18 mVp-p(NTSC)
B = 300
±
18 mVp-p(PAL)
Checking method:
Order Page Address Data
Procedure
1
Perform “Preparations”.
2
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
3
Set the 60i/50i SEL (OTH-
ERS menu) to “60i”.
4
Check the sync signal level
(A) to the NTSC specified
value.
5
Check the burst signal level
(B) to the NTSC specified
value.
6
Set the 60i/50i SEL (OTH-
ERS menu) to “50i”.
7
Check the sync signal level
(A) to the PAL specified
value.
8
Check the burst signal level
(B) to the PAL specified
value.
9
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
10
Perform “Processing after
Complete Adjustment”.
Fig. 6-2-5
H
B
A