8 (E)
HKSP-R80
0 12
3
4
5
67
89A
B
C
D
E F
BIT1 : SYNC/ASYNC selector switch
Used to select whether the communication on the RE-
MOTE1 data link is carried out in synchronization with the
input reference signal that is connected to the REF IN A or
REF IN B connector selected by S802-7, or is communi-
cated asynchronous with the input reference signal.
However, the routing switcher system will operate in the
asynchronous mode if the reference video signal is not
input to the PFV-SP series connector (REF IN A or REF
IN B) even if this switch is set to the SYNC position. Even
when a setting is changed while the power is on, the setting
is reflected on the operation of the HKSP-R80.
ON :
ASYNC (asynchronous mode)
OFF : SYNC (synchronous mode)
BIT2
: BIT3: S/P selector switch
.....
BIT2
: REMOTE1 A connector
.....
BIT3
: REMOTE1 B (B1, B2) connectors
Used to assign the HKSP-R80 either to the primary station
or to the secondary station when the HKSP-R80 is con-
nected to the S-BUS data link with the above connector.
Set BIT2 and BIT3 in accordance with the connector used.
ON :
PRIMARY
OFF : SECONDARY
Even if the setting is changed while the power is on, the
operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the main power and back on, or press
the reset switch (S1201) on the CPU-355 board.
Set the two selector switches in accordance with the
desired operations as shown below.
Operation
S803-2
S803-3
(S-BUS A P/S)
(S-BUS B P/S)
HKSP-R80 operates as
P
P
primary station.
REMOTE1 A is connected
S
P
to higher-level controller
(4093
x
4093 area control)
HKSP-R80 operates as
–
*
1
S
secondary station
P:
PRIMARY
S:
SECONDARY
*
1: When S803-3 is “SECONDARY”, S-BUS A is forced to become
“SECONDARY”.
BIT4: Table data size selector switch
Used to select the S-BUS table data size that is output
when the unit operates as the primary station in the S-BUS
data link of REMOTE1.
ON :
32 bytes
OFF : 128 bytes
BIT5 and BIT6 : Baud rate selector switch
.....
BIT5 : REMOTE1 A connector
.....
BIT6 : REMOTE1 B connector
Sets the baud rate when the HKSP-R80 is connected to the
S-BUS data link using the above connectors.
All of the equipment that are connected to the same S-BUS
data link must have the same setting for the baud rate
speed. Set BIT5 and BIT6 in accordance with the connec-
tors used. Even when a setting is changed while the power
is on, the setting is reflected on the operation of the HKSP-
R80.
If there is any possibility to disconnect the cables between
the equipment while they are operating, set the switch to
the OFF position.
ON :
1250 kbps
OFF : 312 kbps
BIT7: Not used
BIT8: A2 channel valid/invalid switch
Sets whether the S-BUS communications by REMOTE
connector of the PFV-SP series is enabled.
Even when a setting is changed while the power is on, the
setting is reflected on the operation of the HKSP-R80.
ON:
Enabled (The HKSP-R80 is recognized as
REMOTE1 A2 channel)
OFF: Disabled
S804 (A-3) : Test rotary switch
Run the system with 0 (default) position of this switch.
n
Be aware that if S804 is set to 8 or 9, the information
stored in the board may be damaged. In case of setting
S804 to 8, all the information set in the HKSP-R80 may be
erased affecting the operation of the HKSP-R80. In case of
setting S804 to 9, the information in the ROM I
2
C
EEPROM (CPU-355: IC807, CN-2334: IC102, CN-2335:
IC102) will be erased.
Factory setting