9 (E)
HKSP-R80
m
.
When this switch is set to any position of 1 to 5 while
the power is on, the setting is reflected on the operation
of the HKSP-R80. Set this switch to 0 to return to the
normal operation.
.
Even the setting is changed to A to F while the power is
on, the operation mode is not updated. In order to change
the operation mode to A to F, change the setting. Then
re-start the CPU-355 board (either turn off the power and
back on, or press the reset switch (S1201) on the CPU-
355 board). Set this switch to 0 and re-start the CPU-355
board to return to the normal operation.
0 :
Normal operation
The error that is detected first by self-diagnosis is
indicated on the status indicator as an error code.
The error code that is displayed first, is kept stored
until the CPU-355 board is re-started or until this
switch is set to the position 5.
1 :
Displays the station ID (valid during operation).
The station ID of the HKSP-R80 is displayed on the
status indicator.
2 :
Displays the total count of the errors that are
detected by self-diagnosis (decimal number) on the
status indicator.
When the reset switch (S1201) on the CPU-355
board is pressed or this switch is set to “5”, the total
count is re-set to “0000”.
3 :
Displays the IP address (valid during operation).
The IP address set to the HKSP-R80 is displayed on
the status indicator.
4 :
Displays the setting state of the switch (valid during
operation).
The contents of the switches S802 and S803 on the
CPU-355 board are displayed on the status indicator
in hexadecimal.
5 :
Resets the error indication of status indicator (valid
during operation).
When returning the rotary switch from 5 to 0, the
error code displayed on the status indicator is reset,
and “R80” is displayed. (When the BZR-IF810 is
installed in the HKSP-R80, “810” is displayed.)
The total count of error detected by self-diagnosis is
also reset.
6. 7 : Not used
8 :
Factory use only (valid only during startup)
Used for adjustment in the factory.
If this mode is executed, all of the setting data are
deleted. Before executing this mode, implement the
backup of the setup data using the attached BZR-20
software. After execution of the this mode, return
the setup data.
9 :
Factory use only
I
2
C EEPROM (serial ROM) data edit mode (valid
only during startup)
When this mode is executed, the critical informa-
tion on the service stored in the board may be
damaged. When the HKSP-R80 is accidentally
activated in this mode, immediately set this switch
to 0 and restart the HKSP-R80.
A, B : Not used
C :
Clears the system status log.
(Valid only during startup)
Clears the system status log.
D:
Initialization of setting (valid only during startup)
Returns all of the setup items to the default setup
when shipped from the factory. However, the IP
address is not initialized.
E :
Network setting mode (valid only during startup)
Used for the setting, such as the IP address setting
to connect the HKSP-R80 to the network.
For details, refer to Section 4.
F :
Forced program download mode (valid during
startup)
Used for service maintenance.
IF-844 board
Indicator
D1 (B-1): SRX
Lights about 0.015 second when it receives the data from
the S-BUS link.
Switch
S1 (B-3) : RESET
Reset switch of MPU on the IF-844 board.