29 (E)
HKSP-R80
9-4. Downloading the Data
Downloads the various setup data that are saved in a PC, to
the system equipment through primary station.
1.
Install the BZR-20 software. (Refer to Section 9-2.)
2.
Connect the PC to the HKSP-R80 (or connect the PC
to each equipment) and start up the BZR-20 software.
(Refer to Section 9-3, steps 2 to 5.)
3.
Select a desired folder (the folder in the hard disk or
FD drive) in which the setup data are saved, from the
File (F) menu of the menu bar. Press [OK ].
n
You cannot create a new folder at this step.
4.
Select the desired button from “SEND: PC to PRIMA-
RY” column that suits to the contents of the download-
ed data and press the button.
DescriptionF5 : It downloads the names of the total
2048 connectors of the SOURCE
(input) and DESTINATION (output)
that are stored in the PC.
CrosspointF6 : It downloads the latest cross-point
status data (1024 sources and 1024
destinations, level: 8) that are saved in
the PC.
PrimaryF7 :
It returns the setup data of the primary
station to the original state. (The data
as the secondary station that are stored
in the primary station are also returned
to the original state.)
n
The name of the connector and the
cross-point data are not downloaded.
SecondaryF8 : It downloads the setup data of the
secondary equipment that is connected
to the S-BUS remote. Either all of the
setup data that are stored in the
specified folder, or any single speci-
fied secondary station can be selected
for downloading.
Press Cancel (C) to stop downloading.
5.
When downloading is completed, press Exit (E) and
close the BZR-20 window.
The table data that are set using the control terminal is
stored in RAM on the CPU-355 board. Before replacing
the lithium battery, back up the settings using the BZR-20
backup software. (Refer to Section 9.)
n
In the case that the BZR-20 is connected to the S-BUS
subnet controller (Refer to Section 8.), the primary station
indicates the S-BUS subnet controller and the secondary
station indicates the third-level station connected to the S-
BUS subnet controller in the above description.
10. Lithium Battery
A lithium battery is mounted on the CPU-355 board for
backing up RAM and for driving internal watch while the
power is turned off.
Replace the battery before the replacement time shown
below comes. (For details on the procedures for replace-
ment, refer to the maintenance manual.)
Replacement time
Non power-on period of this machine
is shorter than approx. 3 years .
(Because consumption of battery has
started already at the time of
purchase of this machine.)
Non power-on period of this machine
is approx. 3 years.
Period of usage of this machine is
shorter than 5 years.
(Because the battery life is 5 years
and the consumption of the battery
has already started at the time of
purchase of this machine.)
Status of usage of this
machine
The battery has never
been replaced since
purchase of this
machine.
The battery is replaced
by the new battery last
time.
This machine has been
used with always power-
on.