28 (E)
HKSP-R80
9-3. Uploading the Data
Upload the various setup data of the system equipment from primary stations to a PC.
1.
Install the BZR-20 software. (Refer to Section 9-2.)
2.
Turn on the power of all the equipment on the S-BUS data link.
3.
Connect the PC to the REMOTE3 connector or the DATA connector of the HKSP-R80 (or connect
the PC to each equipment). (Refer to Section 9-1.)
4.
Turn on the power of the PC.
5.
Click the BZR-20 icon to start up the BZR-20 software. The following menu appears.
6.
Select a desired folder (any folder in the hard disk or FD drive) in which the uploaded setup data are
saved, from the File (F) menu of the menu bar. Press [OK ].
n
You cannot create a new folder at this step.
7.
Select the desired button from “RECEIVE: PRIMARY to PC” column that suits to the contents of the
uploaded data and press the button.
DescriptionF1 : It uploads the names of the total 2048 connectors of the SOURCE (input) and
DESTINATION (output) that are assigned to the primary station.
CrosspointF2 : It uploads the latest cross-point status data (1024 sources and 1024 destinations,
level: 8) that are saved in the primary station.
PrimaryF3 :
It uploads the setup data that are saved in the primary station.
(The data as the secondary station that are stored in the primary station are uploaded
at the same time.)
n
When uploading the setup data that are stored in the primary station, name of the
connecter and the cross-point data are not included.
SecondaryF4 : It uploads the setup data of the equipment that is connected to the S-BUS remote.
Press Cancel (C) to stop uploading.
8.
When uploading is completed, press Exit (E) and close the BZR-20 window.
Set up the
communication port.
Uploading the data
(Section 9-3)
Select a folder in which the uploaded or
downloaded setup data are saved.
Simplified description of operation manual
Downloading the data
(Section 9-4)