152
Menu List
Ap
pend
ix
e
s
P02
WHITE
COLOR TEMP <A>
Display color
temperature
3200
Sets the color temperature of WHITE A.
(Displayed one is a rough guide only)
C TEMP BAL <A>
(–99 to 99)
0
Adjusts the value more precisely when the
color temperature adjustment through
COLOR TEMP is not satisfactory.
R GAIN <A>
(–99 to 99)
0
Only the value of R GAIN is changed.
B GAIN <A>
(–99 to 99)
0
Only the value of B GAIN is changed.
5600K <A>
OFF/ON
OFF
Turns the WHITE A electronic 5600K filter on/
off.
COLOR TEMP <B>
Display color
temperature
3200
Sets the color temperature of WHITE B.
(Displayed one is a rough guide only)
C TEMP BAL <B>
(–99 to 99)
0
Adjusts the value more precisely when the
color temperature adjustment through
COLOR TEMP is not satisfactory.
R GAIN <B>
(–99 to 99)
0
Only the value of R GAIN is changed.
B GAIN <B>
(–99 to 99)
0
Only the value of B GAIN is changed.
5600K <B>
OFF/ON
OFF
Turns the WHITE B electronic 5600K filter on/
off.
P03
BLACK/FLARE
MASTER BLACK
(–99 to 99)
0
Adjusts the master black level.
R BLACK
(–99 to 99)
0
Adjusts the R black level.
G BLACK
(–99 to 99)
0
Adjusts the G black level.
B BLACK
(–99 to 99)
0
Adjusts the B black level.
MASTER FLARE
(–99 to 99)
0
Adjusts the flare level of the master.
R FLARE
(–99 to 99)
0
Adjusts the R flare level.
G FLARE
(–99 to 99)
0
Adjusts the G flare level.
B FLARE
(–99 to 99)
0
Adjusts the B flare level.
FLARE
OFF/ON
ON
Turns the flare correction circuit on/off.
OUTPUT SELECT
1)
Y/R/G/B
Y
Selects the output signal from the TEST OUT
connector, the input signal to the viewfinder,
and the output signal from the VBS/SDI
OUT
2)
.
P04
GAMMA
GAMMA
OFF/ON
ON
Turns the gamma correction function on/off.
STEP GAMMA
0.35 to 0.90
0.45
Sets the master gamma correction curve in
steps.
MASTER GAMMA
(–99 to 99)
0
Sets the master gamma correction curve.
R GAMMA
(–99 to 99)
0
Sets the R gamma correction curve.
G GAMMA
(–99 to 99)
0
Sets the G gamma correction curve.
B GAMMA
(–99 to 99)
0
Sets the B gamma correction curve.
OUTPUT SELECT
1)
Y/R/G/B
Y
Selects the output signal from the TEST OUT
connector, the input signal to the viewfinder,
and the output signal from the VBS/SDI
OUT
2)
.
GAMMA SELECT
STD/HG
STD
Selects the gamma table.
GAM SEL (STD)
1 to 4
3
Selects the gamma table of STD.
GAM SEL (HG)
1 to 4
4
Selects the hyper gamma table of hyper
gamma.
No.
Page
Item
Settings
Default
Description