5-8
A : XX : XX
W
1,
W
2,
......
1-2-7.
HALL Adjustment
Purpose:
Variation of the HALL element outputs is
removed by adjusting amplifier gain and offset.
The HALL elements detect the lens iris
position.
Adjustment error:
Oscillation of lens iris, or incorrect white
balance indoor and outdoor.
Subject
Not required
Measurement Point
DDS display of EVF or LCD, or
Measuring Instrument
page: A display data of adjustment
remote commander
Adjustment Page
F
Adjustment Address
1E, 1F
Specification
15 to 19h when iris is opened. (Note 1)
88 to 8Ch when iris is closed. (Note 2)
Note 1:
Set page : 6, address : 01, data : 01, and press the PAUSE
button of the adjustment remote commander.
Note 2:
Set page : 6, address : 01, data : 03 and press the PAUSE
button of the adjustment remote commander.
Adjustment procedure:
Note 3:
Lower two digits of the data which is displayed at the
right bottom of he EVF or TV monitor, or the lower 2
digits of the 4 digit display data of page A of the
adjustment remote commander.
Order
Page
Address
Data
Procedure
1
0
01
01
Set the data. (Preparation 1)
2
D
11
02
After setting the data, press the PAUSE button.
3
6
00
01
Set the data. (Preparation 2)
4
6
04
03
Set the data.
5
6
01
03
After setting the data, press the PAUSE button.
6
F
1E
40
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 3). The read-out data is W
2
.
7
F
1E
30
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 3). The read-out data is W
1
.
8
6
01
01
After setting the data, press the PAUSE button.
9
F
1E
30
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 3). The read-out data is K
1
.
10
F
1E
40
After setting the data, press the PAUSE button. Read the data appearing on the DDS
display (Note 3). The read-out data is K
2
.
11
Convert the data W
1
, W
2
, K
1
and K
2
into the decimal numbers. The result decimal numbers
are W
1
', W
2
', K
1
' and K
2
'. (Use page 5-73 “Hexadecimal-Decimal Conversion Table”.)
12
A' = W
2
' + K
1
' – W
1
' –K
2
' ........................................... equation 1
B' = W
1
' –K
1
'
..................................................... equation 2
X
1
' =
1840 + (48
×
A' )–(16
×
B' ) ..................................
equation 3
A'
13
Convert the decimal number X
1
' to the hexadecimal number to obtain X
1
. (Round the
number X
1
to count fractions of 0.5 and over as a unit and cut away the rest.)
14
F
1E
Set the data X
1
(obtained at step 13).
15
Press the PAUSE button.
16
F
1F
Change the data until 17 appears on the DDS display.
17
Press the PAUSE button.
18
6
01
03
After setting the data, press the PAUSE button.
19
If the DDS display shows the data in the range from 88 to 8C, it indicates the end of
adjustment, and proceed to the item “Processing after Adjustments”. If it is not, use the
DDS display data as W
0
and proceed to step 20 and followings.
Summary of Contents for Handycam DCR-PC10
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 45: ...DCR PC10 PC10E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Page 46: ...DCR PC10 PC10E 3 2 POWER SUPPLY BLOCK DIAGRAM 3 6 3 7 3 8 3 9 3 10E ...