5-74
4-2. SERVICE MODE
4-2-1.
Setting the Test Mode
Page D
Address 10
Data
Function
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced VTR power ON
• Set/release each test mode. Set page: 0, address: 01, data: 01 before
setting the data of page D.
• For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjusting remote commander.
In this case, take note that the test mode will not be exited even
when the main power is turned off (8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjusting
remote commander.
Set page: 0, address: 01, data: 00.
4-2-2.
Use History Check
Page 2
Address 35 to 3D
How to use:
1)
The record of use data is displayed at addresses : 35 to 3D on
page 2.
Note:
This data will be cleared when the button battery is removed
(reset). Be sure to read the data before disassembling the
set.
Address
35
36
37
38
39
3A
3B
3C
3D
Function
Hour (H)
Drum rotation counted time (BCD code)
Hour (L)
Hour
Year
User initial power on date (BCD code)
Month
Day
Final condensation occurrence date
Year
(BCD code)
Month
Day
Remarks
1 to 59 minute
1 to 99 hour
100 to 9000 hour
After setting the clock, set the date of power on next.
Summary of Contents for Handycam DCR-PC10
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 45: ...DCR PC10 PC10E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Page 46: ...DCR PC10 PC10E 3 2 POWER SUPPLY BLOCK DIAGRAM 3 6 3 7 3 8 3 9 3 10E ...