5-11
3. Flange Back Adjustment
(Using the flange back adjustment chart)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 300 to 400 lux)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
B6 to BB, BE to C5
Note 1:
Check that the data of page: 2, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens
at TELE end and WIDE end respectively.
3) Check that the data on page: F, address: B6 to BB, BE to C5
are initial value (See table below).
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
02
01
3
2
01
13
Press PAUSE button.
4
2
01
15
Press PAUSE button. (Note 2)
5
2
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B6 to BB and BE to C5.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
2
01
00
Press PAUSE button.
2
3
02
00
3
0
01
00
4
Perform “Flange Back Check”.
Address
Data
Address
Data
B6
CD
BF
00
B7
19
C0
41
B8
92
C1
00
B9
21
C2
19
BA
12
C3
00
BB
14
C4
2E
BE
00
C5
00
Summary of Contents for FD Mavica MVC-FD75
Page 8: ...1 1 SECTION 1 GENERAL MVC FD75 This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 1 10 E ...