2. Flange Back Adjustment (Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
B6 to BB, BE to C5
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 2, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following
figure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance
between it and the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated
power supply is the specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets
the center of shot image screen with the zoom lens
at TELE end and WIDE end respectively.
6) Check that the data on page: F, address: B6 to BB, BE to C5
are initial value (See table below).
Specified voltage: The specified voltage varies according to the
minipatternbox, so adjustment the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage
±
0.01 Vdc
Output current : more than 3.5 A
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
02
01
3
2
01
13
Press PAUSE button.
4
2
01
27
Press PAUSE button. (Note 5)
5
2
02
Check the data changes to
“01”.
Note 5:
The adjustment data will be automatically input to page:
F, address: B6 to BB and BE to C5.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
2
01
00
Press PAUSE button.
2
3
02
00
3
0
01
00
4
Perform “Flange Back
Check”.
Fig. 5-1-9
Address
Data
Address
Data
B6
CD
BF
00
B7
19
C0
41
B8
92
C1
00
B9
21
C2
19
BA
12
C3
00
BB
14
C4
2E
BE
00
C5
00
Summary of Contents for FD Mavica MVC-FD75
Page 8: ...1 1 SECTION 1 GENERAL MVC FD75 This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 1 10 E ...