8. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Mode
CAMERA
Subject
Clear chart
(Color bar standard picture
frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Check the DDS display on the
Measuring Instrument
LCD screen (Note 2)
Adjustment Page
F
Adjustment Address
D3, D4
Specified Value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
“Auto White Balance Standard Data Input” must be
already finished.
Note 2:
The right 4 digits of the displayed data of the LCD screen.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
0
01
01
3
F
11
02
Press PAUSE button.
4
2
10
58
Press PAUSE button.
5
Turn off the HOLD switch.
6
Wait for 2 seconds.
7
Turn on the HOLD switch.
8
E
11
0A
Press PAUSE button.
9
2
01
3F
Press PAUSE button.
10
0
03
04
11
F
D3
Change the data so that
average value of the DDS
displayed data (Note 2)
satisfied the R ratio specified
value.
12
F
D3
Press PAUSE button.
13
0
03
05
14
F
D4
Change the data so that
average value of the DDS
displayed data (Note 2)
satisfied the B ratio specified
value.
15
F
D4
Press PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
2
01
00
Press PAUSE button.
2
0
03
00
3
2
10
00
Press PAUSE button.
4
E
11
15
Press PAUSE button.
5
F
11
00
Press PAUSE button.
6
0
01
00
9. White Balance Check
Mode
CAMERA
Subject
Clear chart
(Color bar standard picture
frame)
Filter
ND filter 1.0 and 0.3
Measurement Point
Check the DDS display on the
LCD screen (Note 1, 2)
Specified Value
When data: 0F is set to page: 2,
address: 01 (Note 1)
R-Y: 00 to 04 or FC to FF
B-Y: 00 to 04 or FC to FF
When data: 00 is set to page: 0,
address: 03 (Note 2)
0E10 or more
Note 1:
Right side 4 digits of data displayed at the LCD screen.
Note 2:
Data displayed at the lower right of the LCD screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
11
02
Press PAUSE button.
2
2
10
58
Press PAUSE button.
3
Turn off the HOLD switch.
4
Wait for 2 seconds.
5
Turn on the HOLD switch.
7
0
03
02
8
2
56
56
Press PAUSE button.
9
2
01
0F
Press PAUSE button.
10
Check that the DDS
displayed data (Note 1) is in a
range of “00 to 04” or “FC to
FF”.
11
0
03
00
12
Check that the DDS
displayed data (Note 2) is
more than “0E10”.
13
Place the ND filter 1.3 (1.0 +
0.3) on the lens.
14
Check that the DDS
displayed data (Note 2) is less
than “0D00”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
2
01
00
Press PAUSE button.
2
2
56
00
Press PAUSE button.
3
2
10
00
Press PAUSE button.
4
F
11
00
Press PAUSE button.
5
0
01
00
00 : XX : XX
Displayed data
00 : XX : XX
Displayed data
00 : XX : XX
R-Y
B-Y
Summary of Contents for FD Mavica MVC-FD75
Page 8: ...1 1 SECTION 1 GENERAL MVC FD75 This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 1 10 E ...