5-9
00 : XX : XX
Displayed data
1-3.
CAMERA SYSTEM ADJUSTMENTS
1. HALL Adjustment
This adjustment sets the amplifier gain and offset to detect the iris
position of the lens.If disordered, the iris will oscillate or the indoor-
outdoor white balance will be faulty.
Mode
CAMERA
Subject
Any subject
Measurement Point
DDS display on the LCD screen
Measuring Instrument
(Note 2)
Adjustment Page
F
Adjustment Address
C7, C8
Specified Value
When data on page: 2, address:
01 is 01, (Note 1)
Displayed data is 12 to 16.
When data on page: 2, address:
01 is 03, (Note 1)
Displayed data is 76 to 7A.
Note 1:
The PAUSE button on the adjustment remote commander
must be pressed.
Note 2:
The right 2 digits of the displayed data of the LCD screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
11
02
Press PAUSE button.
3
0
03
03
4
2
01
03
Press PAUSE button.
5
F
C7
40
Press PAUSE button.
6
Note down the DDS
displayed data (Note 2), and
assume it as W
2
7
F
C7
30
Press PAUSE button.
8
Note down the DDS
displayed data (Note 2), and
assume it as W
1
9
2
01
01
Press PAUSE button.
10
F
C7
30
Press PAUSE button.
11
Note down the DDS
displayed data (Note 2), and
assume it as K
1
12
F
C7
40
Press PAUSE button.
13
Note down the DDS
displayed data (Note 2), and
assume it as K
2
14
Convert W
1
, W
2
, K
1
and K
2
into decimal numbers to get
W
1
’, W
2
’, K
1
’ and K
2
’ (See
table 5-2-2. Hexadecimal-
Decimal Conversion table).
15
Calculate X
1
’ with the
formulas given below
(Calculate decimal numbers).
A’ = W
2
’ + K
1
’ - W
1
’ - K
2
’
B’ = W
1
’ - K
1
’
X
1
’ = 1600 + (48
×
A’) - (16
×
B’) / A’
Order Page Address Data
Procedure
16
Convert X
1
’ into hexadecimal
number to get X
1
(Round off
the decimal place).
17
F
C7
X
1
Press PAUSE button.
18
F
C8
Change the data, so that the
DDS displayed data is “14”.
19
F
C8
Press PAUSE button.
20
2
01
03
Press PAUSE button.
21
Note down the DDS
displayed data (Note 2), and
assume it as W
0
. If W
0
is in a
range of “76 to 7A”, perform
“Processing after Complteing
Adjustment”. If out of the
range, make the following
adjustment.
22
Convert W
0
into decimal
number to get W
0
’.
23
Calculate X
2
’ with the
formulas given below
(Calculate decimal numbers).
C’ = W
0
’ + K
1
’- W
1
’ - 21
X
2
’ = (100 - B’) ( X
1
’ - 48) +
(48
×
C’) / C’
24
Convert X
2
’ into hexadecimal
number to get X
2
.
25
F
C7
X
2
Press PAUSE button.
26
F
C8
Change the data, so that the
DDS displayed data is “78”.
27
F
C8
Press PAUSE button.
28
2
01
01
Press PAUSE button.
29
Confirm that the DDS
displayed data is in a range of
“12 to 16”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
2
01
00
Press PAUSE button.
2
0
03
00
3
F
11
00
Press PAUSE button.
4
0
01
00
Summary of Contents for FD Mavica MVC-FD75
Page 8: ...1 1 SECTION 1 GENERAL MVC FD75 This section is extracted from instruction manual ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 1 10 E ...