5-24
DSC-P71/P71M
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
91
00
4
6
B6
00
5
Release the data setting
performed at step 2.
(Refer to page 5-13)
6
Remove the C14 filter on the
lens.
12. Auto White Balance 5800K Check 1
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Video terminal of
Page: 1
VIDEO OUT jack
(75
Ω
terminated)
Specified Value
Y level data: 20 to C0
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
Perform “Picture Frame
setting”.
(Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to
“01”.
11
6
01
00
Press PAUSE button.
12
6
16
04
13
6
B6
03
14
6
37
0E
15
6
01
C1
Press PAUSE button.
16
6
02
Check the data changes to
“01”.
17
0
03
33
18
1
Check that the Y level data
satisfied the specified value.
19
Perform “ Auto White
Balance 5800K check 2”.