8-22
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-16-7. H Detail Black Clip Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: Open the lens iris by one step from the
reference setting
A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
.
Select the line at the center white portion of the gray-
scale chart.
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S16
*
LEVEL 1
ITEM
: DTL H B. CLIP (Factory setting : 0)
Spec.
: Set the edges of portion B to the
desired clip level.
8-16-8. V Detail Black Clip Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
.
On the set menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: DETAIL
→
ON
ITEM
: TEST OUT
→
ENC
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot a white window chart in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1
Lens IRIS
Spec.
: Open the lens iris by one step from the
reference setting
A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
.
Select the line at the bottom of the center white portion
in the white window chart.
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S16
*
LEVEL 1
ITEM
: DTL V B. CLIP (Factory setting : 0)
Spec.
: Set the level of portion B to the desired
level.
8-16. Detail Signal Adjustment
A
B
B
A