7-21
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
4.
On the setup menu, adjust as follows.
PAGE
: S53
*
VA ADJ. 2/2
ITEM
: B PREKNEE (DCC)
Spec.
: Position the illuminated spot at the
center of the vector monitor.
5.
Repeat steps 3 and 4 several times, position the
illuminated spot at the center of the vector monitor.
6.
Make sure that the carrier leakage at portion B is
minimum.
Setting After Adjustment
.
On the setup menu, set as follows.
PAGE
: S12
*
FUNCTION 1/2
ITEM
: GAMMA
→
ON
ITEM
: TEST SAW
→
OFF
PAGE
: S21
*
LEVEL 4
ITEM
: WHITE CLIP
→
ON
7-15-2. DCC Pre Knee Adjustment
Preparation
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
GAIN switch (inside panel)
→
M (9 dB)
.
WHITE BAL switch (inside panel)
→
PRST
.
On the setup menu, set as follows.
PAGE
: S21
*
LEVEL 4
ITEM
: WHITE CLIP
→
OFF
PAGE
: S12
*
FUNCTION 1/2
ITEM
: TEST OUT
→
G
ITEM
: GAMMA
→
OFF
ITEM
: TEST SAW
→
ON
Adjustment Procedure
Equipment
: Waveform/Vector monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S53
*
VA ADJ. 2/2
ITEM
: G PREKNEE (DCC)
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
2.
On the setup menu, set as follows.
PAGE
: S53
*
VA ADJ. 2/2
ITEM
: TEST OUT
→
ENC
3.
On the setup menu, adjust as follows.
PAGE
: S53
*
VA ADJ. 2/2
ITEM
: R PREKNEE (DCC)
Spec.
: Position the illuminated spot at the
center of the vector monitor.
A
R
M
G
C
Y
G
Y
L
B
B
7-15. Knee and White Clip Adjustments