2-10
DCR-TRV240/TRV340
Adjustment remote
commander (RM-95)
AC IN
DC IN
AC POWER
ADAPTOR
FP-406 flexible
board (30P)
Control switch block
(SS-1380) (12P)
Mechanism deck
CPC-13 jig
(J-6082-443-A)
FP-410
flexible board
FP-411
flexible board
SI-032 board
Battery panel
section
Battery terminal
board (6P)
VC-276
board
LANC
jack
VC-276
Board
A
Cabinet (R) block section
(Raise the hook in the direction of the arrow
A
.)
How to raise the cassette
compartment manually
Control switch block
(CF-2500) (22P)
Harness
(PD-117) (20P)
CN1109
CN1108
12
2
To eject the cassette, short the circuit
between pin
qs
and pin
2
(GND) of
CN1109 on VC-276 board for 1 second.
To check the VTR section, set the VTR to the “Forced VTR power ON” mode.
Operate the VTR functions using the adjustment remote commander (with the HOLD switch set in the OFF position).
[SERVICE POSITION TO CHECK THE VTR SECTION]
Setting the “Forced VTR Power ON” mode
Cnnection to Check the VTR Section
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 02 and
press the PAUSE button of the adjustment remote
commander.
Exiting the “Forced VTR Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
Note : If the machine malfunctions (the operating mode changes by itself), connect the Cabinet (R) section.