5-29
4. Backlight Adjustment (VC-260 board)
Set the backlight luminance.
If deviated, the image may become dark or bright.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
2
of CN002 (EVF BL+)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
90, 91
Specified Value
NORMAL mode : A=1.10 ± 0.05Vdc
BRIGHT mode : B=2.10 ± 0.05Vdc
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
90
Change the data and set the voltage
(A) of Pin
2
of CN002 to the
specified value of NORMAL mode.
3
D
90
Press PAUSE button.
4
D
91
Change the data and set the voltage
(B) of Pin
2
of CN002 to the
specified value of BRIGHT mode.
5
D
91
Press PAUSE button.
6
0
01
00
Set the data.
5. White Balance Adjustment (VC-260 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
D
Adjustment Address
97, 98
Specified Value
The EVF screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC1801
Note2:
Use the AC power adapter.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
97
7E
Set the data, and press PAUSE
button.
3
D
98
80
Set the data, and press PAUSE
button.
4
D
98
Check that the EVF screen is not
colored. If not colored, proceed to
step 10.
5
D
97
Change the data so that the EVF
screen is not colored.
6
D
97
Press PAUSE button.
7
D
98
Change the data so that the EVF
screen is not colored.
8
D
98
Press PAUSE button.
9
D
98
If the EVF screen is colored, repeat
steps 5 to 9.
10
0
01
00
Set the data.
Summary of Contents for DCR-TRV15E
Page 89: ...DCR TRV15E TRV17E 4 57 DIGITAL STILL CONTROL MPEG MOVIE PROCESS MS 070 ...
Page 95: ...DCR TRV15E TRV17E 4 69 4 70 USER FUNCTION CK 101 Uses unleaded solder ...
Page 109: ...5 1 DCR TRV15E TRV17E SECTION 5 ADJUSTMENTS ...
Page 183: ... Take a copy of OPTICAL AXIS FRAME with a clear sheet for use 220 OPTICAL AXIS FRAME ...