5-47
7. Hi8/standard 8 mm Switching Position Adjustment
(VC-235 board)
If deviated in this case causes switching noise or jitter on the Hi8/
standard 8 mm mode played back screen.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: Pin
8
of CN259
(VC RF SWP) on FU-141 board
CH2: Pin
5
of CN259 (PB RF) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
62, 63
Specified Value
t1=0 ± 10 µsec
Adjusting Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 22, set data: C0, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 2, address: 2E, and set data: 02.
4) Set to the playback mode.
5) Select page: F, address: 62, change the data and minimize “t1”,
and then press the PAUSE button. (Coarse adjustment)
6) Select page: F, address: 63, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
7) Press the PAUSE button.
8) Select page: F, address: 22, set data: 80, and press the PAUSE
button.
9) Select page: 2, address: 2E, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-7
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
8. CAP FG Duty Adjustment (VC-235 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Playback
Signal
Hi8/standard 8 mm alignment tape:
For checking operation
(WR5-5NSP (NTSC))
(WR5-5CSP (PAL))
Measurement Point
Pin
qg
of CN259 (CAP FG) on
FU-141 board
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
64
Specified value
Duty=50 ± 1%
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 2E, and set data: 02.
3) Set to the playback mode.
4) Select page: 6, address: 01, set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up auto-
matic CAP FG offset adjustment)
5) Select page: 6, address: 02, and check that the data is “01”.
6) Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 6, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 4) to 6).
7) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
8) Select page: 2, address: 2E, and set data: 00.
9) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-8
A
B
Duty = A/B
×
100 [%]
Center of movement