5-26
9. Light Level Adjustment and ND shutter check
Adjust the standard LV value.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
Display data of page 1 (Note 2)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
26, 28
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: Below 1100
Note 1:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Note 2:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Adjusting method:
1)
Select page: 0, address: 01, set data: 01 and press the PAUSE
button.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
(The light level adjustment is performed and the adjustment
data is stored in page: F, address: 26, 28.)
4)
Select page: 6, address: 02, and check that the data is “01”.
5)
Select page: 0, address: 03, set data: 06, and press the PAUSE
button.
6)
Select page: 1, and check that the display data (Note 2) satisfies
the AE level 1
7)
Select page: E, address: 41, set data: 6B, and press the PAUSE
button.
8)
Select page: 6, address: 1C, set data: 03, and press the PAUSE
button.
9)
Select page: 1, and check that the display data (Note 2) satisfies
the AE level 2.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, and set data: 00.
2)
Select page: E, address: 41, set data: 6A, and press the PAUSE
button.
3)
Select page: 6, address: 1C, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
8. AGC Standard Gain and Max Gain Adjustment
Adjust the AGC standard gain and max gain.
Mode
STILL
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
E
F
Adjustment Address
4F
27
Note:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: 6, address: 98, and set data: C0.
4)
Select page: 6, address: 99, and set data: 26.
5)
Select page: 6, address: 01, and set data: C7, and press the
PAUSE button of remote commander. (The AGC gain
adjustment is performed and the adjustment data is stored in
page: E, address: 4F, and page: F, address 27.)
6)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 98, and set data: 00.
2)
Select page: 6, address: 99, and set data: 00.
3)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Cyber-shot DSC-F505
Page 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...