5-39
9. White Balance Adjustment (HI-70 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
82, 83
Specified Value
The LCD screen should not be colored.
Note 1:
Use the AC power adaptor during this adjustment.
Note 2:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC802 (LCD DRIVE)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 02.
3)
If used AC adapter, select page: D, address: 1C, after noting
the data, set data: 00, and press PAUSE button.
If used battery, select page: D, address: 1D, after noting the
data, set data: 0C.
4)
Select page: D, address: 82 and 83, set the data to the initial
value.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
5)
Check that the LCD screen is not colored. If colored, change
the data of page: D, address: 82 and 83 so that the LCD screen
is not colored.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
6)
Select page: D, address: 1C or 1D, set the data noted down at
step 3).
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Address
Data
82
B9
83
B7
Fig.5-1-25.
A
A
A
A
B
B
B
B
8. V-COM Adjustment
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
88
Specified Value
The brightness difference between the
section A and section B is minimum.
Note 1 :
Perform “Bright Adjustment” and “Contrast Adjustment” before
this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: 01.
3)
Select page: 2, address: 10, and set data: 02.
4)
Select page: D, address: 88, change the data so that the
brightness of the section A and that of the section B is equal.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 5, address: F1, and set data: 00.
7)
Select page: 2, address: 10, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Cyber-shot DSC-F505
Page 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...