5-38
7. V-COM Level Adjustment (Control Switch Block (FK) )
Set the common electrode drive signal level of LCD to the specified
value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
8
of CN002 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
86
Specified Value
A= 6.50 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 03.
3)
Select page: D, address: 86, change the data and set the COM
signal level (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Fig.5-1-23.
A
2H
Green
White (100%)
A
2H
Fig.5-1-24.
6. Color Adjustment (Control Switch Block (FK) )
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin
9
of CN002 (VG)
External trigger: Pin
8
of CN002
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
81
Specified Value
A= 544 ± 50mV
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, set data: 04.
3)
Select page: D, address: 81, change the data and set the voltage
(A) between the white 100% (Reference level) and green to
the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 5, address: F1, set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Cyber-shot DSC-F505
Page 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...