5-28
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: B, address: 41, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: F, address: 37, set data: 93, and press the PAUSE
button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: 0, address: 01, and set data: 00.
12. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note 3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
3F, 40, 80
Specified Value
R ratio: 29E0 to 2B20 (Center: 2A80)
B ratio: 5F20 to 6060 (Center: 5FC0)
Note 1:
Perform “Auto White Balance ND Filter Compensation
Adjustment” and “Auto White Balance Standard Data Input” before
this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Note 3:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Adjusting method:
1)
Place the C14 filter for color temperature correction on the
lens.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: B, address: 41, set data: 30, and press the PAUSE
button.
5)
Select page: F, address: 37, set data: 9B, and press the PAUSE
button.
6)
Select page: 6, address: 01, set data: A7, and press the PAUSE
button.
7)
Select page: F, address: 49 to 4C, and note down the data of
each address.
8)
Input the following data to page: F, addresses: 49 to 4C.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
9)
Select page: 6, address: 01, set data: A5, and press the PAUSE
button.
(The auto white balance adjustment is performed and the
adjustment data is stored in page: F, address: 3F, 40 and 80.)
10) Select page: 6, address: 02, and check that the data is “01”.
11) Select page: 6, address: 01, set data: 3F, and press the PAUSE
button.
12) Select page: 0, address: 03, and set data: 04.
13) Select page: 1, and check that the display data (Note3) satisfies
the R ratio specified value.
14) Select page: 0, address: 03, and set data: 05.
15) Select page: 1, and check that the display data (Note3) satisfies
the B ratio specified value.
16) Select page: F, address: 49 to 4C, and input the data noted down
at step 7).
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
Address
Data
49
2A
4A
80
4B
5F
4C
C0
Summary of Contents for Cyber-shot DSC-F505
Page 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...