5-32
16. Strobe Light Level and White Balance Check
Check the light level regulation and the white balance when the
strobe light flashes.
Mode
STILL
Subject
Flash adjustment box (Note4)
(1.0m from the front of the lens)
Measurement Point
Display data of page: 1
Measuring Instrument
Adjustment remote commander
Specified value
Y level data: 68 to A0 (Note6)
R-Y data: FA to FF or 00 to 06 (Note7)
B-Y data: FA to FF or 00 to 06 (Note7)
Note 1:
Perform this adjustment in the flash adjustment box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of
“HALL Adjustment”, “Flange Back Adjustment”, “Light Level
Adjustment”, “Auto White Balance Adjustment” and “Strobe White
Balance Adjustment”.
Note 4:
Refer to “4. Preparing the Flash Adjustment Box”. (See page 5-7)
Note 5:
Check that the data of page: 6, address: 02 is “0”. If not, turn the
power of the unit OFF/ON.
Note 6:
Display data of page 1 of the adjustment remote commander.
1 : 00 : XX
Y level data
Note 7:
Display data of page 1 of the adjustment remote commander.
1 : XX : XX
B-Y data
R-Y data
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: 6, address: 90, and set data: 00.
4)
Select page: 6, address: 91, and set data: 00.
5)
Select page: 6, address: 92, and set data: 00.
6)
Select page: 6, address: 93, and set data: 60.
7)
Select page: 6, address: 2C, and set data: 01.
8)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
9)
Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
10) Check the flashing of the strobe light.
11) Select page: 0, address: 03, and set data: 01.
12) Select page: 1, and check that the Y level data satisfies the
specified value. (Note6)
13) Select page: 0, address: 03, and set data: 02.
14) Select page: 1, and check that the R-Y data and B-Y data satisfy
the specified value respectively.(Note7)
Processing after Completing Adjustments:
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 2C, and set data: 00.
3)
Select page: 6, address: 93, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: E, address: 8F, set data: 01, and press the PAUSE
button.
6)
Select page: E, address: 6F, set data: 24, and press the PAUSE
button.
7)
Select page: E, address: 71, set data: 10, and press the PAUSE
button.
8)
Select page: F, address: B9, set data: 00, and press the PAUSE
button.
9)
Select page: 5, address: F1, and set data: 00.
10) Select page: 0, address: 01, and set data: 00.
17. CCD Black Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of the lens)
(Note1)
Measurement Point
Display data of page: 6, address: 55
Measuring Instrument
Adjustment remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Specified value
Data < 0A: OK, Data > 0B: NG
Note 1:
Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2:
Any subject other than the clear chart should not be in the screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: F, address: DF, after noting down the data, set
data: 4C, and press the PAUSE button.
4)
Select page: 6, address: 2C, and set data: 01.
5)
Select page: 6, address: 90, and set data: 00.
6)
Select page: 6, address: 91, and set data: 03.
7)
Select page: 6, address: 92, and set data: 00.
8)
Select page: 6, address: 93, and set data: 00.
9)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
10) Select page: 6, address: 30, set data: 07, and wait for four
seconds.
11) Select page: 6, address: 01, set data: 8D, and press the PAUSE
button.
(The CCD Block defect compensation is performed and the
adjustment data is stored in page: 7, address: 60 to 87.)
12) Select page: 6, address: 02, and check that the data changes to
“01”.
13) Select page: 6, address: 55 and check that the data satisfies
specified value.
(This value means the number of the Black CCD defect.)
Processing after Completing Adjustments:
1)
Select page: F, address: DF, set the data noted down at step 3),
and press the PAUSE button.
2)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 91, and set data: 00.
5)
Select page: 6, address: 30, and set data: 00.
6)
Select page: 5, address: F1, and set data: 00.
7)
Select page: 0, address: 01, and set data: 00.
Summary of Contents for Cyber-shot DSC-F505
Page 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 8: ...1 2 ...
Page 9: ...1 3 ...
Page 10: ...1 4 ...
Page 11: ...1 5 ...
Page 12: ...1 6 ...
Page 13: ...1 7 ...
Page 14: ...1 8 ...
Page 15: ...1 9 ...
Page 16: ...1 10 ...
Page 17: ...1 11 ...
Page 18: ...1 12 ...
Page 19: ...1 13 ...
Page 20: ...1 14 ...
Page 21: ...1 15E ...