1-10 (E)
BDX-N1000
1-7. Internal Switches and Indicators
1
2
3
S1
ON
1
2
3
4
A
B
C
Factory setting
( indicates the switch lever position.)
(Side A/Component side)
(Side A/Component side)
1
2
3
S100
A
B
C
D
Factory setting
ON
1
2
3
4
5
6
7
8
( indicates the switch lever position.)
1-7-3. CCM-36A Board (BDKP-N1002)
n
.
The number shown in parenthesis ( ) indicates address
on the board.
.
Do not change settings of the switch that is specified as
“Factory use only”.
S1 (B-1) : Factory use only
Factory setting : S1-1 : OFF
S1-2 : ON
S1-3 : ON
S1-4 : ON
1-7-4. CCM-40 Board (BDKP-N1003)
n
.
The number shown in parenthesis ( ) indicates address
on the board.
.
Do not change settings of the switches that are specified
as “Factory use only” and “Unassigned”.
S100 (C-1): Mode select switch
S100-1 : Factory use only
Factory setting : ON
S100-2 : Factory use only
Factory setting : ON
S100-3 : Factory use only
Factory setting : OFF
S100-4 : Factory use only
Factory setting : ON
S100-5 : Transmission cable length select switch
Set the switch according to the length of the cable
connected to the ATM I/O connector on the rear
panel.
ON : When the length of the cable is 68 m or
more
OFF : When the length of the cable is less than 68 m
Factory setting : OFF