1-9 (E)
BDX-N1000
1-7. Internal Switches and Indicators
1
2
3
S1
ON
1
2
3
4
A
B
C
Factory setting
( indicates the switch lever position.)
(Side A/Component side)
1-7-2. CCM-36 Board (BDKP-N1001)
n
.
The number shown in parenthesis ( ) indicates address
on the board.
.
Do not change settings of the switch that is specified as
“Factory use only”.
S1 (B-1) : Factory use only
Factory setting : S1-1 : OFF
S1-2 : OFF
S1-3 : ON
S1-4 : ON
S600-8 :
FLASH ROM (CH0) write-protection select
switch
CLOSE : Write-protection function ON
OPEN :
Write-protection function OFF
Factory setting : CLOSE (lower position)
S601 (A-1) : Factory use only
n
Do not press this switch in normal operation.
S602 (F-1, E-1) : Factory use only
Factory setting : All switch levers are set to ON.
S603 (F-1, E-1) : Factory use only
Factory setting : All switch levers are set to ON.
S604 (G-1, F-1) : Factory use only
Factory setting : All switch levers are set to ON.
S1100 (J-5, G-5) : Factory use only
Factory setting : All switch levers are set to ON.
1)
S1101 (G-5) : Unassigned
Factory setting : 0
1)
S1102 (G-5) : Factory use only
Factory setting : 0
1)
S1103 (G-5) : Factory use only
Factory setting : 0
S1600 (A-1) : Reset switch
n
Do not press this switch in normal operation.
n
1) : Serial No. 10001 to 10843 only.