1-4. Rack Mounting
The BDX-N1000 can be mounted in a 19-inch standard
rack.
n
.
If the BDX-N1000 or the peripheral equipment is
mounted in a 19-inch standard rack, it is recommended
to install a ventilation fan to prevent a temperature rise in
the rack.
Make sure that all the units in the rack should be operat-
ed within the temperature range of 5
d
C to 40
d
C.
.
Connect the enough long cables on the rear panel,
considering that the BDX-N1000 is pulled out.
.
An installation manual is supplied with the RMM-30
rack mount rail. However follow the instructions in this
manual. Because the rack mounting procedures of the
BDX-N1000 are different from the procedures explained
in RMM-30 installation manual.
.
Be sure to fix the rack to the floor with bolts.
This will prevent the rack from falling when the unit is
pulled out from the rack.
Required parts
.
Rack mount rail (RMM-30)
Rail with bracket :
2 pcs.
Screw (B 5
x
8) :
4 pcs.
Screw (PWH 4
x
10) : 2 pcs.
Plate nut :
2 pcs.
.
Screw for inner rail (B 4
x
8)
*
1
:
6 pcs.
.
Screw for rack mounting (RK 5
x
16) : 4 pcs.
(Sony part number: 7-682-378-04)
.
Washer for rack mounting :
4 pcs.
(Sony part number: 2-297-913-01)
*
1 : The BDX-N1000 comes with the eight screws. The two screws of them
are spare.
n
Be sure to use the RMM-30 rack mount rail.
If a rack mount rail other than the RMM-30 is used, the
BDX-N1000 may be dropped by insufficient strength of
the rack mount rail. This may cause a injury.
Procedures
1.
Turn the power off.
2.
Remove the four feet from the bottom of the BDX-
N1000.
3.
While pressing the stopper of the rail, pull out the
inner rail.
1-4. Rack Mounting
Feet
BVTT 3
x
12
Feet
BVTT 3
x
12
Outer rail
Stopper
Inner rail