1-8 (E)
BDX-N1000
1-7. Internal Switches and Indicators
Suffix : -12
(Side A/Component side)
A
B
C
D
E
F
J
H
G
K
1
2
3
4
5
6
S601
S600
S1600
S603 S604
S602
ON
1
2
3
4
5
6
7
8
OPEN
12
3
4
5
6
7
8
S1100
8
0
4
C
9 A
B
D
E
F
12
3
5
6
7
Factory setting
( indicates the switch lever position.)
Factory setting
Factory setting
1-7. Internal Switches and Indicators
1-7-1. IF-694 Board
S600 (A-1): Mode select switch
n
After the following settings are changed, turn the power
off and on again.
S600-1 to -4: Minor alarm output conditions select switches
Sets the conditions of outputting the minor
alarm signal from the ALARM connector on
the rear panel. These switches are used to
set in which conditions of the Tx LED and
the Rx LED on the front panel, the minor
alarm shall be output. (It consists of logic
OR of the Tx LED status and the Rx LED
status.)
S600-1
S600-2
Tx LED status
OPEN
OPEN
When turned off or turned on in red
OPEN
CLOSE
When turned on in red
CLOSE
OPEN
When turned off
CLOSE
CLOSE
Not related to the Tx LED
(factory setting)
S600-3
S600-4
Rx LED status
OPEN
OPEN
When turned off or turned on in red
OPEN
CLOSE
When turned on in red
CLOSE
OPEN
When turned off
CLOSE
CLOSE
No relation with the Rx LED
(factory setting)
example : When the switches S600-1 and
S600-4 are closed while S600-2
and S600-3 are opened, the minor
alarm is output under the follow-
ing conditions.
.
When the Tx LED is lit off or
the Rx LED is lit on in red
S600-5 :
Maintenance mode select switch
CLOSE : Normal operation
OPEN : Maintenance mode
Factory setting : CLOSE (lower position)
S600-6 :
Unassigned
Factory setting : CLOSE (lower position)
S600-7 :
FLASH ROM (CH1) write-protection select
switch
CLOSE : Write-protection function OFF
OPEN :
Write-protection function ON
Factory setting : CLOSE (lower position)
< Serial No. 20001 and Higher >
Suffix : -11
(Side A/Component side)
A
B
C
D
E
G
F
H
1
2
3
4
5
6
S601
S600
S1600
S603 S604
S602
S1102 S1101
S1100
S1103
8
0
4
C
9A
B
D
EF
12
3
5
67
ON
1
2
3
4
5
6
7
8
Factory setting
OPEN
12
3
4
5
6
7
8
Factory setting
Factory setting
( indicates the switch lever position.)
< Serial No. 10001 to 10843 >
n
.
The number shown in parenthesis ( ) indicates address
on the board. When the address is different depending on
the machine serial numbers, address will have the
following indication to show the applicable machine
serial numbers.
.
Do not change settings of the switches that are specified
as “Factory use only” and “Unassigned”.
(x-x, x-x)
S/N : 20001 and Higher
S/N : 10001 to 10843