3
Product description
sonnenBatterie hybrid 8.1-5.5
8.1/6
8.1/8
8.1/10
8.1/12
8.1/14
8.1/16
Safety
Protection class
I / PE conductor
Required fault current monitoring
Residual current device (RCD) | Type B | 30 mA
Degree of Protection
IP30
Rated short-time withstand
current (I
CW
)
10 kA
Separation principle
no galvanic isolation, transformer-less
Dimensions / weight with small extension cabinet (from 6 kWh up to 10 kWh)
Dimensions (H/W/D) in cm
137/67/23
-
-
-
Weight in kg
133
160
187
-
-
-
Dimensions / weight with big extension cabinet (from 6 kWh up to 16 kWh)
Dimensions (H/W/D) in cm
187/67/23
Weight in kg
144
171
198
225
252
279
Power meter
Voltage measurement inputs
Nominal voltage (AC): 230 V (L-N), 400 V (L-L) |
max. connectible conductor cross-section: 1.5 mm
2
Clamp-on current transformer
Max. measurable current: 60 A (standard), optional up to 400 A
Ambient conditions
Environment
indoor (conditional)
Ambient temperature range
5 °C … 30 °C
Storage temperature range
0 °C … 40 °C
Transport temperature range
-15 °C … 40 °C
Max. rel. humidity
90 %, non-condensing
Permissible installation altitude
2,000 m above sea level
Pollution degree
2
Additional ambient conditions
•
The installation location must not be at risk of flooding.
•
Installation room should be ventilated.
•
The currently applicable building codes must be observed.
•
Even floor, suitable for heavy loads.
•
Observe fire control standards.
•
Free from corrosive and explosive gases (ammonia content max. 20 ppm).
•
Free from dust (especially flour dust or sawdust).
•
Free from vibrations.
•
Free access to the installation location.
•
No direct sunlight.
Table 2: Technical data
12 / 68
KD-421 | Part no. 22136 | EN | X03