7-15
7.5 Angle adjustment of the clinometer
When the hoisting system is mounted on the ship, it is necessary that the “FWD”
direction of the clinometer in the
hoist control box
conforms to the “FWD” direction of the
transducer.
2-1) Check for the mounting direction.
The connector side of the clinometer is the bow side.
If this is not the case, change the mounting direction as follows.
①
Before starting the task, remove screw A and remove the clinometer together
with the base plate from the
hoist control box
.
②
Remove screw B and change the direction of the clinometer in increments of
90° before mounting the clinometer again.
③
To change in increments of 45°, remove hexagonal spacer C to change
direction and attach it again to the clinometer plate.
2-2
)
Inclination adjustment
The inclination of the clinometer board can be horizontally adjusted.
Loosen three hexagonal nuts D and adjust the height of lower nuts E.
After the adjustment, tighten nuts D.
FWD
Clinometer plate
Base plate
Connector
Clinometer PCB
Summary of Contents for SCS-60
Page 1: ...Model SCS 60 Scanning Sonar Operation Manual Ver 5 00E Rev 0...
Page 2: ...MEMO...
Page 12: ...x MEMO...
Page 16: ...1 4 MEMO...
Page 32: ...4 6 MEMO...
Page 50: ...5 18 MEMO...
Page 70: ...6 20 MEMO...
Page 86: ...7 16 MEMO...
Page 94: ...8 8 MEMO...