OPERATING MANUAL PAT-806 version 1.08
16
Notes:
- Nominal network voltage is used in
I
SUB
function for calculating the leakage current, which is meas-
ured at a voltage of 40V and its value is rescaled to the nominal voltage.
3.3.8 Setting current values in the measurement of R
PE
on IEC lead test
Press
ENTER
.
Use
,
to set
the test current (10 A
or 200 mA).
Press
ENTER
, to confirm the set-
tings, or
ESC
, to exit to main MENU
without changing any settings.
3.3.9 Configuration of settings from PC
"Sonel PAT" software and "Sonel Reader" freeware delivered with the meter, enable user to con-
figure meter settings, both in terms of general data and individual parameters of each measurement
function.
When using "Sonel PAT" software - start to configure the settings by pressing
Settings
1 button
displayed in the main window (
Main functions
tab), then in "Software settings" window press
Meter
settings
2 .