7
EN
- SLIDYMOOVE 300 installation and operating guide - SOMFY
E
N
!
Concrete base
Gate
Metal plate
Ø25 / Ø32
250 mm min.
260 mm min.
260 mm min.
260 mm min.
≈ 194 mm
≈ 194 mm
≈ 194 mm
≈ 25 mm
Wall/pillar
The
concrete base on which the motor will be installed must comply with the dimensions indicated on
the diagram below.
!
Check the height of the rack
1.
Position the motor in the intended location (on dry concrete).
2.
Place the pencil on the side notches of the motor intended for
this purpose.
The pencil makes a mark on the gate brace: case of standard
installation, see page 9.
The pencil makes a mark above the brace: case of specific
installation, see page 11.