5
EN
- SLIDYMOOVE 300 installation and operating guide - SOMFY
E
N
Prerequisites for installation
!
Stop blocks on the ground
!
Positioning the motor
!
Electrical pre-equipment
The gate travel must be defined by end stops firmly fixed in the ground.
Closing end stop
Opening end stop
Gate
Concrete base
Feed for 230V power
supply cables
and the main accessories
Caps to be drilled
if necessary to
accommodate
additional cables
Cables required
•
Power supply: 3 x 1.5 mm² cable or
3 x 2.5 mm² for outdoor use
(type H07RN-F minimum)
•
Linking of cells: 2 x 0.75 mm² cable
•
Other accessories: see page 6
Provision must be made for the supply cable
to be fed through according to the electrical
standards in force in the country of use.
If a cable conduit cannot be made, use a cable
grommet which will withstand the passage of
vehicles (ref. 2400484).
Cable feed
•
Underground cables must be equipped with a
protective sheath with a sufficient diameter to
contain all the cables.
•
Fit a 230 V electrical input as close as possible
to the motor.